The test bench uses water, ethylene glycol or antifreeze as the working medium, and is used for repeated pressure tests (pressure alternation/pulse tests) on pressure-bearing components such as pipelines, heater cores, automobile water pumps, and various cavities.
During the test, the working medium at a specified temperature circulates in the inner cavity of the specimen, and at the same time, a pulse pressure of a certain number of cycles is applied to the inner cavity of the specimen according to the specified frequency, pressure, and curve.
The test bench is fully automatically controlled, the entire equipment is simple to operate, stable in performance, cost-effective, and easy to maintain. The test bench has the functions of automatically performing pulse tests, recording and saving data such as the number of impacts, temperature, and frequency. In addition, leakage faults of systems and components can be automatically preliminarily judged.

1. Test product
Automobile water pump
Product flow range: 19~300L/min
Water pump diameter Φ15, Φ20, Φ25, Φ30, Φ40, Φ50;
Sample reserved interface: 1-3 pieces;
2. Pressure parameters
Control mode: Fully automatic control
Pressure realization mode: Air pressure liquid mode, change the air pressure to achieve the pressure of the liquid;
Test pressure: Pressure peak 0.1~0.5MPa can be set arbitrarily
Pressure control accuracy ±2%F.S;
Test frequency: 0.1-1Hz;
Frequency control Error: ±1cycle/min;
Waveform adjustment:
Sine wave (high/low pressure, frequency, can be set arbitrarily);
Triangle wave (high/low pressure, rise/fall time, can be set arbitrarily);
Square wave (high/low pressure, frequency, can be set arbitrarily);
Trapezoidal wave (high/low pressure, rise/fall/high/low pressure time, can be set arbitrarily);
3. Medium temperature control system parameters
Test medium: water, ethylene glycol, antifreeze (boiling point is 20℃ higher than the test temperature)
Temperature range: RT+10 ~135℃, fixed value control,
Average heating rate ≥2℃/min;
Control accuracy: ±3℃;
4. Flow parameters
Flow only monitors the reading value, monitoring range: 30~300L/min, sensor accuracy ±1%F.S;
5. Environmental chamber parameters
Temperature range: RT+10~150℃; fixed value control;
Control accuracy: ±2℃, temperature deviation ±2℃;
Average heating rate ≤3℃/min; (25℃→150≤45min)
Test room space: length 1200×width 1000×height 800mm